Sign In | Join Free | My benadorassociates.com
China Guangzhou GENY Electric Co., Ltd logo
Guangzhou GENY Electric Co., Ltd
Professional in Energy Meter Testing
Verified Supplier

2 Years

Home > Stationary Meter Test Bench >

YC1893D-ICT Meter Testing Bench Closed Links Meter Test System With ICT

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

YC1893D-ICT Meter Testing Bench Closed Links Meter Test System With ICT

  • 1
  • 2

Brand Name : GENY

Model Number : YC1893D-ICT

Certification : ISO, CE

Place of Origin : China

MOQ : 1

Price : negotiate rates

Payment Terms : T/T, L/C, D/P, T/T

Supply Ability : 5 sets / 1 months

Delivery Time : 6~8weeks

Packaging Details : Plywood cases

Accuracy : 0.05

Number Of Meter Positions : 6/12/24/48

Structure : All-in-one

Power Source : YCS-103-250 YCS-103-600 YCS-103-1200 YCS-103-2500

Test voltage output (Phase-Neutral) : 3x(24V~288V)(or customized)

Stability : Better than 0.005%/h (integration time 150 s)

Material : Aluminum Alloy

Contact Now

Professional Stationary Meter Test Equipment for Closed Links Meters with ICT

Three Phase Closed Links Meter Test System

Technical Data:

  • Accuracy class : 0.05
  • Easy to calibrate I-P closed links meters with isolated current transformer(ICT)

Technical spec. YC1893D-ICT-6 YC1893D-ICT-12 YC1893D-ICT-24 YC1893D-ICT-48
Number of meter positions equipped ICT 6 12 24 48
Accuracy class of ICT 0.05 / 0.01
Accuracy 0.05
Power Source YCS-103-250 YCS-103-600 YCS-103-1200 YCS-103-2500
Standard Meter SZ03A-K6 / SZ03A-K8 (customized)
Scanning Head YCG-S Series
Voltage
Test voltage output(Phase-Neutral) 3x(24V~288V)(or customized)
Power of the voltage output Max. 3x100VA Max. 3x250VA

Max.

3x500VA

Max.

3x1000VA

Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005% /h (integration time 150s)
Load regulation from 0~max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonic 2nd~21st free programmable
Current
Test current output 3x(1mA~100A)
Power of the current output Max. 3x150VA Max. 3x350VA Max. 3x750VA Max. 3x1500VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005% /h (integration time 150s)
Load regulation from 0~max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonic 2nd~21st free programmable
Phase angle
Range 0~360⁰
Resolution 0.01⁰
Setting accuracy 0.1⁰
Frequency
Range 45Hz~65Hz
Resolution 0.01Hz
Error display
Type of error display Red LED
Resolution of error displays 8 digitals
Other
Voltage supply

3x220/380V±10%(or customized)

50/60Hz ±2Hz

Ambient temperature -10°C~+40°C
Relative humidity 35%~85%

Description:

1. Install the ICT in each meter position to test three-phase meters with closed current and voltage measuring circuits (I-P links).
2. The meter test system can measure mechanical meters, electronic mechanical meters, and electronic meters through automatic, semi-automatic, or manual operations.
3. Meters being tested: 3P4W, 3P3W, 1P2W.
4. Testing modes: active power, reactive power, cross-connected reactive power.
5. Simultaneously measure meters with the same specifications but different meter constants.
6. Automatically position the rotor mark of the disc of the mechanical meter, with higher efficiency.
7. Starting test and creeping test.
8. With protection functions of overload, short voltage circuit, and open current circuit.
9. The swing of the scanning heads together simplifies the control.
10. Made of aluminum alloy material, light, strong, and corrosion-resistant.
11. The testing software with a friendly Windows 2000/XP/7/8/10 operating system includes functional modules of various modern energy meters required to realize error testing, harmonic testing, demand testing, influence testing, etc.

Applications:

1. National utility companies
2. Governmental metrology bureaus
3. Large energy meter manufacturers

Primary Competitive Strengths:

1. High quality product

2. Over 18 months long warranty

3. High accuracy class: 0.05
*** highest accuracy can reaches to 0.01% under 3 meter positions***

4. 3~48 Three Phase Electric Energy Meter Test bench

5. Extremely high power stability

6. Timing error test

7. Influence test of voltage, frequency, and harmonic

8. Installing RS232, Ethernet communication port in each meter position.

9. Tilt impact test (optional)

YC1893D-ICT Meter Testing Bench Closed Links Meter Test System With ICT


Product Tags:

yc1893d-ict meter testing bench

      

closed links meter test system

      

meter testing bench closed links

      
Quality YC1893D-ICT Meter Testing Bench Closed Links Meter Test System With ICT for sale

YC1893D-ICT Meter Testing Bench Closed Links Meter Test System With ICT Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou GENY Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)